If you don't remember your password, you can reset it by entering your email address and clicking the Reset Password button. You will then receive an email that contains a secure link for resetting your password
If the address matches a valid account an email will be sent to __email__ with instructions for resetting your password
The use of curved linear array (CLA) and radial EUS in the lower GI tract has largely been limited to the sigmoid colon and rectum, as their oblique optics present a challenge in advancement to the right side of the colon. While catheter-based miniprobes are available for endosonographic assessment of lesions in the right side of the colon, they are limited by the inability to perform fine-needle biopsies (FNBs). Recently, a double-balloon endoluminal intervention platform (DEIP) has become available to aid in EMR and endoscopic submucosal dissection. The DEIP consists of a soft, flexible sheath equipped with 2 manually inflatable balloons: a “fore” or front balloon, and an “aft” or rear balloon. Together, these balloons are designed to create a stable “therapeutic zone” during EMR or endoscopic submucosal dissection. However, the DEIP may also aid in cecal intubation, as retraction of the sheath and endoscope with an inflated aft-balloon shortens the colon, allowing for the endoscope to be advanced further. We present a case in which a DEIP was used to advance a radial and CLA echoendoscope into the cecum for evaluation of a submucosal lesion at the appendiceal orifice.
Case
An asymptomatic 56-year-old man was referred to our practice after a screening colonoscopy revealed a 20-mm submucosal lesion at the appendiceal orifice. A contrast-enhanced CT scan of the abdomen and pelvis noted an ill-defined mixed soft tissue density just inferior to the cecum of unclear etiology and clinical significance (Fig. 1). The patient was evaluated by general surgery for a discussion of surgical options but favored a conservative approach and repeat endoscopic evaluation with EUS. A decision was made to therefore perform DEIP-assisted EUS of the lesion.
Figure 1CT imaging demonstrating soft tissue density at the cecum.
A pediatric colonoscope equipped with a DEIP (DiLumen; Lumendi, Westport, Conn, USA) (Fig. 2) was advanced to the cecum where a 20-mm submucosal lesion was seen at the appendiceal orifice (Video 1, available online at www.giejournal.org). The aft-balloon was inflated, and the DEIP was left in place, after which a radial echoendoscope (Olympus, Center Valley, Pa, USA) was passed through a slit cut into the sheath of the DEIP, and advanced into the cecum. Radial EUS demonstrated a hypoechoic lesion arising from the fourth layer (muscularis propria). The radial echoendoscope was then exchanged for a CLA echoendoscope (Olympus) through the DEIP, and the linear EUS revealed an irregular 33- × 16-mm hypoechoic mass (Fig. 3). FNB of this lesion was then performed using a 22-gauge US biopsy needle using a transcolonic approach. Final pathology demonstrated a leiomyoma (Fig. 4), and the patient was able to avoid an unnecessary surgery.
High-quality EUS using radial and CLA echoendoscopes have enabled accurate diagnoses of submucosal lesions in the GI tract; however, lesions in the right side of the colon have often remained out of reach. To our knowledge, this is the first reported use of a DEIP for the facilitation of EUS with FNB in the lower GI tract. This technique is reproducible throughout the entire colon and may also be beneficial in settings where mucosal biopsies are inconclusive and core biopsy specimens need to be obtained. While there are forward-viewing echoendoscopes that may allow conventional cecal intubation, they are not widely available and have a narrower scanning range (90⁰) compared with CLA echoendoscopes (180°).
By functioning similar to a single-balloon enteroscope, the DEIP offers a degree of familiarity to most endoscopists but is instead equipped with manually inflatable balloons. This alleviates the need for additional equipment and offers a simpler learning curve to support staff. While our case demonstrated this technique to be safe and effective, special attention should be made during insertion of the echoendoscopes, and the assistance of fluoroscopy should be considered. Additionally, careful consideration should always be taken prior to pursuing FNB in the lower GI tract, as adverse events such as perforation and bacteremia have been reported.
While further studies of this technique are necessary to assess its true safety and efficacy, our case demonstrates that with use of a DEIP, high-quality EUS with FNB can be performed in the right side of the colon, allowing for an accurate diagnosis. Use of this technique should be considered in the investigation of lesions in the proximal colon.
Disclosure
Dr Tyberg is a consultant for Boston Scientific and EndoGastric Solutions. Dr Kahaleh has received grant support from Boston Scientific, Fujinon, W.L. Gore, Apollo Endosurgery, Cook Endoscopy, ASPIRE Bariatrics, Merit Medical, Olympus and MI Tech. He is a consultant for Boston Scientific, Microtech, Medtronic and AbbVie. All other authors disclosed no financial relationships.